SVC-T12 · AUTOMATION & SCADA COMMISSIONING

Control System Testing & SCADA Services in Pakistan.

TransfoLine provides turnkey Control System Testing, Substation Automation, and PLC/SCADA Commissioning Services across Pakistan. We execute rigorous cold and hot loop checks, emergency trip matrix verification, safety interlocking logic validation, and protocol testing (IEC 61850, Modbus, DNP3) to ensure 100% fail-safe automated plant operation.

ANALOG & DIGITAL I/O CHECKS TRIP MATRIX VERIFICATION IEC 61850 & MODBUS PROTOCOL SCADA / HMI INTEGRATION
Substation automation and PLC control panel testing in Lahore Pakistan
LOOP CHECK ACCURACY
100% Point-to-Point
SUPPORTED PROTOCOLS
IEC 61850 / Modbus
REPORT DELIVERY
24 Hours
01
  EXECUTIVE SUMMARY

What is Control System Testing & SCADA Commissioning?

Control system testing is the thorough functional validation of programmable logic controllers (PLC), remote terminal units (RTU), supervisory control and data acquisition (SCADA) servers, and safety instrumented systems (SIS). It guarantees that all field sensor signals, auto-sequencing logic, safety interlocks, and emergency trip commands function flawlessly before plant energization.

01

End-to-End I/O Loop Verification

Every single analog input (4-20mA temperature, pressure, level transmitters) and digital output (breaker trip, pump start/stop contacts) is injected and confirmed at the SCADA screen with calibration records.

02

Interlock & Safety Shutdown Logic

We test mechanical and electrical interlocks (e.g. breaker-isolator interlocking, dual source auto-transfer schemes, and fire alarm emergency trips) to prevent dangerous operational sequencing errors.

02
  COMMISSIONING SCOPE

Automation & Control Diagnostics We Perform

CTRL.01 Cold & Hot I/O Loop Testing Signal continuity, 24V DC loop power checks, 4-20mA calibration, and confirmation of graphic tag animations on SCADA/HMI operator consoles. Loop Checking
CTRL.02 Emergency Trip & Cause-and-Effect Matrix Full simulation of emergency stop pushbuttons, transformer trip inputs (Buchholz, PRD, OTI/WTI), and generator reverse power trips. Trip Matrix
CTRL.03 Substation Automation (IEC 61850 GOOSE) Network packet analysis and verification of high-speed peer-to-peer GOOSE trip messaging and MMS client/server communications between numerical IEDs. IEC 61850 Testing
CTRL.04 Sequence of Events (SOE) Time Sync Verifying GPS / NTP / IRIG-B clock synchronization across all protection relays and RTUs to ensure sub-millisecond timestamp accuracy during fault investigations. SOE Time Sync
03
  COMMUNICATION PROTOCOLS

Industrial Automation Platforms & Protocols Tested

Protocol / Standard Application Supported Vendors Testing Verification Tool
IEC 61850 (GOOSE / MMS) Substation Automation & Fast Tripping Siemens SIPROTEC, Schneider MiCOM, ABB Relion OMICRON IEDScout / Wireshark
Modbus TCP & RTU (RS485) Energy Meters, VFDs, Battery Chargers Schneider, Siemens, Mitsubishi, Delta, Socomec ModScan32 / Protocol Analyzer
DNP3 / IEC 60870-5-104 Grid Telemetry to National Control Center (NPCC) SEL, ABB, Siemens SICAM RTUs ASE2000 Protocol Test Set
04   AUTOMATION FAQ

Frequently Asked Questions.

Technical advice on control system commissioning.

FAT & SAT What is the difference between FAT and SAT?

Factory Acceptance Testing (FAT) tests control panels and software logic in our workshop before dispatch. Site Acceptance Testing (SAT) verifies the fully installed system on-site with actual field cabling, sensors, and switchgear connected.

TELEMETRY Can TransfoLine commission SCADA connections to DISCO/NTDC grid centers?

Yes. We configure and test RTUs transmitting real-time voltage, current, breaker status, and tap changer telemetry to DISCO (LESCO, GEPCO, K-Electric) and NTDC control centers using IEC 104 and DNP3 protocols.

06
  GET STARTED

Book Control System & SCADA Testing.

Our automation and protection engineers deploy nationwide across Pakistan.

Need I/O loop checking, PLC logic debugging, or substation SCADA commissioning? Contact us directly.